Dayton Audio RS100P-4 standard | Fs 85 Hz, 86.0 dB, Qts 0.540 | LoudspeakerLab

Dayton Audio RS100P-4 standard measurements on LoudspeakerLab. 86.0 dB sensitivity. Fs 85 Hz. Qts 0.540. Evidence grade C+ (56.8/100).

Preview

Thiele-Small parameters

Fs: 85 Hz; Qts: 0.540; Qes: 0.670; Qms: 2.670; Vas: 1.86 L; Sd: 36.3 cm²; Re: 3.00 Ω; Le: 0.26 mH; Sensitivity: 86.0 dB; Nominal Z: 3.2 Ω; Measured range: 20-19346 Hz

Driver quality scores

On-axis flatness 72 · DI tracking 0 · DI smoothness 22

Usable passband

Scored passband 127 Hz–13.3 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~2.9 L · Fb 72 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (56.8/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from Dayton Audio

Manufacturer