Dayton Audio ND28F-6 standard | Fs 1097 Hz, 87.2 dB, Qts 1.240 | LoudspeakerLab

Dayton Audio ND28F-6 standard measurements on LoudspeakerLab. 87.2 dB sensitivity. Fs 1097 Hz. Qts 1.240. Evidence grade C+ (55.6/100).

Preview

Thiele-Small parameters

Fs: 1097 Hz; Qts: 1.240; Qes: 2.940; Qms: 2.160; Sd: 4.9 cm²; Re: 5.40 Ω; Le: 0.08 mH; Sensitivity: 87.2 dB; Nominal Z: 5.7 Ω; Measured range: 300-20000 Hz

Driver quality scores

On-axis flatness 78 · DI tracking 76 · DI smoothness 31

Usable passband

Scored passband 2354 Hz–10.9 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (55.6/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from Dayton Audio

Manufacturer