Dayton Audio ND140-8 standard measurements on LoudspeakerLab. 83.0 dB sensitivity. Fs 56 Hz. Qts 0.680. Evidence grade C+ (56.8/100).
Fs: 56 Hz; Qts: 0.680; Qes: 0.790; Qms: 5.010; Vas: 7.74 L; Sd: 86.6 cm²; Re: 7.80 Ω; Le: 1.44 mH; Sensitivity: 83.0 dB; Nominal Z: 8.7 Ω; Measured range: 20-20000 Hz
On-axis flatness 62 · DI tracking 44 · DI smoothness 57
Scored passband 85 Hz–4.4 kHz
Spec-sheet profiles · Off-axis H/V response data available.
Sealed ~12.3 L
LoudspeakerLab evidence grade: C+ (56.8/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.