Dayton Audio DC200-8 standard measurements on LoudspeakerLab. 85.1 dB sensitivity. Fs 30 Hz. Qts 0.420. Evidence grade C+ (56.8/100).
Fs: 30 Hz; Qts: 0.420; Qes: 0.490; Qms: 3.060; Vas: 45.70 L; Sd: 211.2 cm²; Re: 6.41 Ω; Le: 2.32 mH; Sensitivity: 85.1 dB; Nominal Z: 7.1 Ω; Measured range: 20-20000 Hz
On-axis flatness 61 · DI tracking 94 · DI smoothness 84
Scored passband 45 Hz–962 Hz
Spec-sheet profiles · Off-axis H/V response data available.
Vented ~40.5 L · Fb 32 Hz
LoudspeakerLab evidence grade: C+ (56.8/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.