Dayton Audio PCS175-4 standard | Fs 56 Hz, 86.9 dB, Qts 0.980 | LoudspeakerLab

Dayton Audio PCS175-4 standard measurements on LoudspeakerLab. 86.9 dB sensitivity. Fs 56 Hz. Qts 0.980. Evidence grade C+ (56.8/100). 1 public design.

Preview

Thiele-Small parameters

Fs: 56 Hz; Qts: 0.980; Qes: 0.980; Qms: 2.850; Vas: 0.48 L; Sd: 143.0 cm²; Re: 3.70 Ω; Le: 0.80 mH; Sensitivity: 86.9 dB; Nominal Z: 4.1 Ω; Measured range: 5-40000 Hz

Driver quality scores

On-axis flatness 63 · DI tracking 63 · DI smoothness 74

Usable passband

Scored passband 82 Hz–3.7 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Sealed ~1.1 L

Measurement profiles

Public designs

1 public loudspeaker design on LoudspeakerLab use this driver.

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (56.8/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from Dayton Audio

Manufacturer