Dayton Audio DSA135-8 standard | Fs 52 Hz, 85.9 dB, Qts 0.380 | LoudspeakerLab

Dayton Audio DSA135-8 standard measurements on LoudspeakerLab. 85.9 dB sensitivity. Fs 52 Hz. Qts 0.380. Evidence grade C+ (57.0/100). 1 public design.

Preview

Thiele-Small parameters

Fs: 52 Hz; Qts: 0.380; Qes: 0.470; Qms: 2.040; Vas: 7.93 L; Sd: 75.4 cm²; Re: 5.90 Ω; Le: 0.78 mH; Sensitivity: 85.9 dB; Nominal Z: 6.4 Ω; Measured range: 20-20000 Hz

Driver quality scores

On-axis flatness 72 · DI tracking 64 · DI smoothness 46

Usable passband

Scored passband 78 Hz–4.6 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~5.7 L · Fb 60 Hz

Measurement profiles

Public designs

1 public loudspeaker design on LoudspeakerLab use this driver.

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from Dayton Audio

Manufacturer