Purifi PTT10.0X04-NAB-01 standard measurements on LoudspeakerLab. 88.3 dB sensitivity. Fs 24 Hz. Qts 0.330. Evidence grade C+ (57.0/100). 1 public design.
Fs: 24 Hz; Qts: 0.330; Qes: 0.350; Qms: 5.500; Vas: 82.00 L; Sd: 360.0 cm²; Re: 3.90 Ω; Le: 0.62 mH; Sensitivity: 88.3 dB; Nominal Z: 4.7 Ω; Measured range: 20-20000 Hz
On-axis flatness 65 · DI tracking 20 · DI smoothness 38
Scored passband 46 Hz–2.5 kHz
Spec-sheet profiles · Off-axis H/V response data available.
Vented ~44.9 L · Fb 32 Hz
1 public loudspeaker design on LoudspeakerLab use this driver.
LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.