FaitalPRO 8FE300 (16 Ohm) standard | Fs 70 Hz, 92.4 dB, Qts 0.660 | LoudspeakerLab

FaitalPRO 8FE300 (16 Ohm) standard measurements on LoudspeakerLab. 92.4 dB sensitivity. Fs 70 Hz. Qts 0.660. Evidence grade C+ (57.0/100).

Preview

Thiele-Small parameters

Fs: 70 Hz; Qts: 0.660; Qes: 0.700; Qms: 12.600; Vas: 14.40 L; Sd: 223.0 cm²; Re: 11.80 Ω; Le: 0.82 mH; Sensitivity: 92.4 dB; Nominal Z: 14.0 Ω; Measured range: 20-20000 Hz

Driver quality scores

On-axis flatness 55

Usable passband

Scored passband 124 Hz–5.9 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Sealed ~23.9 L

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from FaitalPRO

Manufacturer