FaitalPRO 10FE300 (8 Ohm) standard | Fs 50 Hz, 93.6 dB, Qts 0.520 | LoudspeakerLab

FaitalPRO 10FE300 (8 Ohm) standard measurements on LoudspeakerLab. 93.6 dB sensitivity. Fs 50 Hz. Qts 0.520. Evidence grade C+ (57.0/100).

Preview

Thiele-Small parameters

Fs: 50 Hz; Qts: 0.520; Qes: 0.540; Qms: 13.100; Vas: 50.50 L; Sd: 358.0 cm²; Re: 5.80 Ω; Le: 0.60 mH; Sensitivity: 93.6 dB; Nominal Z: 7.0 Ω; Measured range: 20-20000 Hz

Driver quality scores

On-axis flatness 61

Usable passband

Scored passband 74 Hz–2.4 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~72.8 L · Fb 44 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from FaitalPRO

Manufacturer