FaitalPRO 18HP1060 (4 Ohm) standard | Fs 35 Hz, 94.0 dB, Qts 0.330 | LoudspeakerLab

FaitalPRO 18HP1060 (4 Ohm) standard measurements on LoudspeakerLab. 94.0 dB sensitivity. Fs 35 Hz. Qts 0.330. Evidence grade C+ (57.0/100).

Preview

Thiele-Small parameters

Fs: 35 Hz; Qts: 0.330; Qes: 0.340; Qms: 13.300; Vas: 184.40 L; Sd: 1212.0 cm²; Re: 2.90 Ω; Le: 1.09 mH; Sensitivity: 94.0 dB; Nominal Z: 4.2 Ω; Measured range: 20-20000 Hz

Driver quality scores

On-axis flatness 45

Usable passband

Scored passband 52 Hz–2.0 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~100.9 L · Fb 47 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from FaitalPRO

Manufacturer