FaitalPRO 15HP1060 (8 Ohm) standard | Fs 40 Hz, 94.3 dB, Qts 0.310 | LoudspeakerLab

FaitalPRO 15HP1060 (8 Ohm) standard measurements on LoudspeakerLab. 94.3 dB sensitivity. Fs 40 Hz. Qts 0.310. Evidence grade C+ (57.0/100).

Preview

Thiele-Small parameters

Fs: 40 Hz; Qts: 0.310; Qes: 0.320; Qms: 11.400; Vas: 100.30 L; Sd: 842.0 cm²; Re: 5.00 Ω; Le: 1.32 mH; Sensitivity: 94.3 dB; Nominal Z: 6.9 Ω; Measured range: 20-20000 Hz

Driver quality scores

On-axis flatness 58

Usable passband

Scored passband 64 Hz–1.8 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~49.3 L · Fb 56 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from FaitalPRO

Manufacturer