FaitalPRO 12PR310 (8 Ohm) standard | Fs 54 Hz, 97.9 dB, Qts 0.400 | LoudspeakerLab

FaitalPRO 12PR310 (8 Ohm) standard measurements on LoudspeakerLab. 97.9 dB sensitivity. Fs 54 Hz. Qts 0.400. Evidence grade C+ (57.0/100).

Preview

Thiele-Small parameters

Fs: 54 Hz; Qts: 0.400; Qes: 0.410; Qms: 11.600; Vas: 73.50 L; Sd: 533.0 cm²; Re: 5.40 Ω; Le: 0.61 mH; Sensitivity: 97.9 dB; Nominal Z: 6.6 Ω; Measured range: 20-20000 Hz

Driver quality scores

On-axis flatness 53

Usable passband

Scored passband 82 Hz–3.4 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~59.3 L · Fb 60 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from FaitalPRO