FaitalPRO 10RS430 (8 Ohm) standard | Fs 32 Hz, 92.0 dB, Qts 0.280 | LoudspeakerLab

FaitalPRO 10RS430 (8 Ohm) standard measurements on LoudspeakerLab. 92.0 dB sensitivity. Fs 32 Hz. Qts 0.280. Evidence grade C+ (57.0/100).

Preview

Thiele-Small parameters

Fs: 32 Hz; Qts: 0.280; Qes: 0.290; Qms: 10.000; Vas: 59.20 L; Sd: 344.0 cm²; Re: 6.80 Ω; Le: 0.78 mH; Sensitivity: 92.0 dB; Nominal Z: 8.8 Ω; Measured range: 20-20000 Hz

Driver quality scores

On-axis flatness 56

Usable passband

Scored passband 50 Hz–2.4 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~24.3 L · Fb 50 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from FaitalPRO

Manufacturer