FaitalPRO 10RS350 (4 Ohm) standard | Fs 40 Hz, 90.3 dB, Qts 0.310 | LoudspeakerLab

FaitalPRO 10RS350 (4 Ohm) standard measurements on LoudspeakerLab. 90.3 dB sensitivity. Fs 40 Hz. Qts 0.310. Evidence grade C+ (57.0/100).

Preview

Thiele-Small parameters

Fs: 40 Hz; Qts: 0.310; Qes: 0.330; Qms: 6.200; Vas: 40.60 L; Sd: 344.0 cm²; Re: 3.20 Ω; Le: 0.45 mH; Sensitivity: 90.3 dB; Nominal Z: 4.0 Ω; Measured range: 20-20000 Hz

Driver quality scores

On-axis flatness 63

Usable passband

Scored passband 62 Hz–3.6 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~19.9 L · Fb 56 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from FaitalPRO

Manufacturer