Beyma 6MI100 (8 Ohm) standard | Fs 128 Hz, 96.0 dB, Qts 0.510 | LoudspeakerLab

Beyma 6MI100 (8 Ohm) standard measurements on LoudspeakerLab. 96.0 dB sensitivity. Fs 128 Hz. Qts 0.510. Evidence grade C (47.0/100).

Preview

Thiele-Small parameters

Fs: 128 Hz; Qts: 0.510; Qes: 0.550; Qms: 8.600; Vas: 3.10 L; Sd: 140.0 cm²; Re: 6.00 Ω; Le: 0.20 mH; Sensitivity: 96.0 dB; Nominal Z: 6.8 Ω; Measured range: 20-19484 Hz

Driver quality scores

On-axis flatness 55

Usable passband

Scored passband 191 Hz–2.7 kHz

Measurement coverage

Spec-sheet profiles

Recommended enclosure

Vented ~4.3 L · Fb 114 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C (47.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from Beyma

Manufacturer