Beyma 5MP60N (8 Ohm) standard | Fs 63 Hz, 90.5 dB, Qts 0.460 | LoudspeakerLab

Beyma 5MP60N (8 Ohm) standard measurements on LoudspeakerLab. 90.5 dB sensitivity. Fs 63 Hz. Qts 0.460. Evidence grade C (47.0/100).

Preview

Thiele-Small parameters

Fs: 63 Hz; Qts: 0.460; Qes: 0.580; Qms: 2.300; Vas: 5.80 L; Sd: 85.0 cm²; Re: 5.33 Ω; Le: 0.20 mH; Sensitivity: 90.5 dB; Nominal Z: 5.3 Ω; Measured range: 20-19390 Hz

Driver quality scores

On-axis flatness 50

Usable passband

Scored passband 95 Hz–8.2 kHz

Measurement coverage

Spec-sheet profiles

Recommended enclosure

Vented ~6.3 L · Fb 62 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C (47.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from Beyma

Manufacturer