Beyma 10MI100 (8 Ohm) standard | Fs 50 Hz, 96.1 dB, Qts 0.210 | LoudspeakerLab

Beyma 10MI100 (8 Ohm) standard measurements on LoudspeakerLab. 96.1 dB sensitivity. Fs 50 Hz. Qts 0.210. Evidence grade C (47.0/100).

Preview

Thiele-Small parameters

Fs: 50 Hz; Qts: 0.210; Qes: 0.220; Qms: 6.600; Vas: 54.00 L; Sd: 380.0 cm²; Re: 6.30 Ω; Le: 0.90 mH; Sensitivity: 96.1 dB; Nominal Z: 9.4 Ω; Measured range: 20-19861 Hz

Driver quality scores

On-axis flatness 43

Usable passband

Scored passband 101 Hz–3.5 kHz

Measurement coverage

Spec-sheet profiles

Recommended enclosure

Vented ~14.3 L · Fb 107 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C (47.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

More from Beyma

Manufacturer