Scan-Speak 10F/8414G10 standard | Fs 100 Hz, 86.0 dB, Qts 0.510 | LoudspeakerLab

Scan-Speak 10F/8414G10 standard measurements on LoudspeakerLab. 86.0 dB sensitivity. Fs 100 Hz. Qts 0.510. Evidence grade C+ (57.0/100).

Preview

Thiele-Small parameters

Fs: 100 Hz; Qts: 0.510; Qes: 0.650; Qms: 2.440; Vas: 1.57 L; Sd: 36.3 cm²; Re: 6.30 Ω; Le: 0.11 mH; Sensitivity: 86.0 dB; Nominal Z: 8.0 Ω; Measured range: 23-5998 Hz

Driver quality scores

On-axis flatness 89 · DI tracking 0 · DI smoothness 3

Usable passband

Scored passband 175 Hz–20.0 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~2.2 L · Fb 89 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

Manufacturer