SB Acoustics SB34NRXL75-8 standard | Fs 22 Hz, 91.0 dB, Qts 0.280 | LoudspeakerLab

SB Acoustics SB34NRXL75-8 standard measurements on LoudspeakerLab. 91.0 dB sensitivity. Fs 22 Hz. Qts 0.280. Evidence grade A- (80.0/100).

Preview

Thiele-Small parameters

Fs: 22 Hz; Qts: 0.280; Qes: 0.290; Qms: 5.500; Vas: 205.00 L; Sd: 508.0 cm²; Re: 6.20 Ω; Le: 1.20 mH; Sensitivity: 91.0 dB; Nominal Z: 5.0 Ω; Measured range: 20-20000 Hz

Driver quality scores

On-axis flatness 61 · DI tracking 51 · DI smoothness 80

Usable passband

Scored passband 52 Hz–1.5 kHz

Measurement coverage

Measured profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~84.3 L · Fb 34 Hz

Measurement profiles

Measurement quality

LoudspeakerLab evidence grade: A- (80.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.