SB Acoustics SB17CAC35-8 standard | Fs 28 Hz, 86.5 dB, Qts 0.360 | LoudspeakerLab

SB Acoustics SB17CAC35-8 standard measurements on LoudspeakerLab. 86.5 dB sensitivity. Fs 28 Hz. Qts 0.360. Evidence grade C+ (57.0/100).

Preview

Thiele-Small parameters

Fs: 28 Hz; Qts: 0.360; Qes: 0.400; Qms: 4.460; Vas: 42.00 L; Sd: 118.0 cm²; Re: 5.70 Ω; Le: 0.15 mH; Sensitivity: 86.5 dB; Nominal Z: 8.0 Ω; Measured range: 21-18946 Hz

Driver quality scores

On-axis flatness 56 · DI tracking 58 · DI smoothness 38

Usable passband

Scored passband 40 Hz–2.7 kHz

Measurement coverage

Spec-sheet profiles · Off-axis H/V response data available.

Recommended enclosure

Vented ~27.2 L · Fb 34 Hz

Measurement profiles

Where to buy

Measurement quality

LoudspeakerLab evidence grade: C+ (57.0/100). Based on measurement provenance, off-axis data, distortion, and T/S completeness.

Manufacturer